Home Quickscreen Brochure Page 1 Quickscreen Brochure Page 2 Quickscreen Brochure Page 3 Quickscreen Brochure Page 4

 

 

Positive: A rose-pink band is visible in each control zone (top band). No color band appearing in the appropriate test zone (bottom band) indicates a prelimi­nary positive result for the corresponding drug of that specific test zone. Send urine specimen to a certified laboratory for confirmation

Negative: A rose-pink band is visible in each control zone and the appropriate test zone, indicating that the concentration of the corresponding drug of that specific test zone is below the detection limit of the test.

Retest: If a color band is not visible in each of the control zones, the test is invalid. Another test should be run to re-evaluate the specimen.

Note: There is no meaning attributed to line color intensity or width.

LIMITATIONS OF THE TEST

1.    This product is designed to be used for the detection of drugs of abuse and
their metabolites in human urine only.

2.    Although the test is very accurate, there is the possibility false results will
occur due to the presence of interfering substances in the specimen sample.

3.    The test is a qualitative screening assay and is not suggested for quantitative
determination of drug levels in urine, or the level of intoxication.

4.   Adulterants such as bleach or other strong oxidizing agents, when added to

The following Marijuana-related substances yield positive results for Marijuana at 50 ng/ml cut-off:

ll-Nor-∆◦-THC-9-COOH               50 ng/ml

ll-Nor-∆◦-THC-9-COOH               50 ng/ml

∆◦-THC                                          1 µg/ml

∆◦-THC                                          4 µg/ml

Cannabinol                                    10 µg/ml

ll-Hydroxy-∆◦-THC                       10 µg/ml

 

The following Opiates-related substances yield a positive result for Opiates at

2000 ng/ml Cut-Off Level:

Morphine                                     2,000 ng/ml

Morphine-3-β-D-Glucuronide      2,000 ng/ml         Lewrphaiml        6,000   ng/ml

Codeine                                      2,000  ng/ml        Naloxone         10,000   ng/ml

Heroin                                          2,000 ng/ml         Thekahie          15,000  ng/ml

Nurcodeine                                20,000 ng/ml        Imipramine     500,000   ng/ml          Hydrocodeine                           5,000 ng/ml        Atropine       1,000,000  ng/ml

Hydromorphone                          2,000 ng/ml          Meperidine   1,000,000   ng/ml

Oxycodone                             100,000 ng/ml          Roniltidine    1,000,000   ng/ml

 

The following Phencyclidine (PCP)-related substances yield positive results for PCP:

n-Acelylprocainamide                                   10,000  ng/ml

Codeine                                                          5,000  ng/ml

p-Hydroxymethamphetamine                        50,000  ng/ml

Thebaine                                                       10,000  ng/ml

l-(I-Phenylcyclohexyl)morphine                          600  ng/ml

N,N-Diethyl-l-phenyl-cyclohexyIamine                2.0  ng/ml

l-[1-(2-Thienyl)cyclohexyl]morphine                   200 ng/ml

Phencyclidine                                                        25 ng/ml
l-(-4-Hydroxypiperjdino)phenylcyclohexane      550 ng/ml

1-(1phenylcycohexyl)pyrrolidine                          00 ng/ml

4-phenyl- 4piperidino cyclohexanol                      60 ng/ml

1-[1-(2-Thienyl)-cyclohexyl]piperidine                  30 ng/ml

1—[1-(2-Thienyl)-cyclohexyl]pyrrolidine             600 ng/ml

 

Table II:     Compounds tested and found not to cross-react with the test at a speci­fied urine concentrator.

The following compounds do not cross-react with (1000 ng/ml cut-off) Amphetamine at a 100 /Jg/ml concentration in urine:

5.    urine specimens, can cause erroneous test results regardless of the analysis
method used.   If adulteration is suspected, obtain another urine specimen.

PERFORMANCE CHARACTERISTICS

1 . Sensitivity. The QuikScreen” 5 detects drugs of abuse and their major metabolites in urine at concentrations equal to or greater than the cut-off level for the specific drug, which is suggested by the U.S. Substance Abuse and Mental Health Services Administration (SAMHSA) for the immu-noassay method.

2. Specificity. A study was conducted with the QuikScreen* 5 to determine the cross-reactivity of drug-related compounds with the test. Substances listed in Table I produced results approximately equivalent to the cutoff levels. A separate study was conducted to determine the cross-reactivity of non-related compounds with the test at concentrations much higher than normally found in the urine of people using or abusing them. No cross reactivity was detected with the substances listed in Table II.

 

Table I: Concentrations of drug-related compounds showing positive

response approximately equivalent to the cut-off set for the test:

 

The following Amphetamine-related substances yield positive results for

Acetaminophen

Acetylsalicylic Acid

Am ikacin

Amitriptyline

Ampicillin, Sodium Salt

Arterenol

Aspartame

Airopine

Benzoic Acid

Benzoylecgonine

Caffeine

(+)   Chlorpheniramine

Maleate

(+-)Chlorpheniramine

Maleate

Chlorpromazine HCI

Cimetidine

Codeine

Dextromethorphan  HBr

Diazepam

5,5–Diphenylhydantoin

Doxylamine

Ecgonine  HCI

Ecgonine Methyl Ester

Glucose

Histamine

Hydrochlorothiazide

Hydrocodone

Hydromorphone

Idomethacin

Ketoprofen

Levorphanol

∆◦-THC

(-) l l-Nor-∆◦-THC-9-COOH

Meperidine

Methylphenidate

Methodone

Methaqualone

Morphine-3 -d-Glucuronide

Morphine Sulfate

Oxazepam

Oxycodone

Phendimetrazine

Penicillin  G

Pentobarbitial

d-Propoxyphene

1-Propanol

Quinine

Ranitidine

Sodium Salicylate

Tryptophan

Tetracyline

Tetrahydrozoline

Tetracyline

Theophylline

Thioridazine

Trifluoperazine

Amphetamine at 1000 ng/ml cut-off:

 

The following compounds do not cross with (300 ng/ml cut –off ) Amphetamine at a 100 ng/ml concentration in urine:

j-Amphetamine        1000 ng/ml       β-Phenyleamine                               180,000 ng/ml

l- Amphetamine   50,000  ng/ml      Tyramine                                           120,000 ng/ml

d,l- Amphetamine 1,250ng/ml   (i) 3, 4-Methylenedioxyamphetanine (MDA)  500 ng/ml

                                                 Pseudoephedrine                                5,000,000 ng/ml

Deoxyephedrine          1,000,000 ng/ml      Epededrine                     10,000,000 ng/ml 

Phentermine                     50,000 ng/ml

(i)Phenypropanolamine    50,000 ng/ml

The following Cocaine-related substances yield positive results for Cocaine at 300 ng/ml Cut-Off Level

Benzoylecgonine              300 ng/ml

Cocaine                             300 ng/ml

Isoxsuprine                    2,500 ng/ml

 

Acetaminophen

Acetylslicylic

Am ikacin

Amitriptyline

Ampicillin

Arterenol

Aspartame

Atropine

Benzoic Acid

Caffeine

Chlorpheniramine

Chlorpromazine HCI

Cimetidine

Codeine

Deoxyephedrine

Dextromethorphan

Diazepam

Diethylpropion

5,5-Diphenylhydantoin

Doxylamine

 

Ecogonine HCI

Ecgonine Methyl Ester

Glucose Pentobarbitial

Histamine

Hydrochlorothiazide

Hydrocodone

Hydromorphone

Idomethacin

Ketoprofen

Levorphanol

∆◦-THC

ll-Nor-∆◦-THC-9-COOH

Meperidine

Methylphenidate

Methodone

Methaqualone

Morphine-3-β-d-Glucurondine

Morphine

Oxazepam

Oxycodone

Phendimetrazine

Penicillin  G

Pentobarbitial

d-Propoxyphene

1-Propanol

Phencyclidine

Phenobarbital

Phenermine

Phenylpropamine

1- Phenylephrines

Quinine

Ranitidine

Sodium Salicylate

Tetracycline

Tetrahydrozoline

Theophylline

Thioridazine

Trifluperazine

Tryprophan